IZOLRUT – cold shrink set for connecting cables and wires

Description

IZOLRUT - zimnokurczliwy zestaw do łączenia kabli oraz przewodów
IZOLRUT - zimnokurczliwy zestaw do łączenia kabli oraz przewodów
IZOLRUT - zimnokurczliwy zestaw do łączenia kabli oraz przewodów
IZOLRUT - zimnokurczliwy zestaw do łączenia kabli oraz przewodów

Application:

Repair kits of the type IZOLRUT can be used in underground workings of Mining Plants and in specialist repair workshops underground and on the surface:

  • when connecting mining power cables with insulation, sheath and thermoplastic sheath for a voltage of 0.6 / 1 kV, 3.6 / 6 kV and 6 / 10kV and cross-sections of working conductors 35mm2 – 185mm2,
  • when connecting and repairing mining sheath cables with cross-sections of working conductors 25mm2 – 95mm2,
  • when connecting screened signaling cables to a rated voltage not exceeding 0.6 / 1 kV,
  • when connecting unshielded signaling cables to rated voltage not exceeding 0.6 / 1 kV,
  • when connecting mining telecommunications cables,
  • when connecting telecommunications cables for opencast Mining Plants,
  • for connecting shielded signaling and telecommunications cables,
  • for connecting unshielded signaling and telecommunications cables.

 

 

Selection of IZOLRUT sets to the types and cross-sections of the connected wires and cables

Kits for connecting and repairing tensioned tire cables 0,6/1kVCross-section of connected working conductors
Tire hoses repair kit “IZOLRUT 6-O” 
L-680mm, Ø-72mm, 35-70mm2 , 0,6/1kV
35 mm2 – 70 mm2
Tire hoses repair kit “IZOLRUT 8-O” 
L-700mm, Ø-98mm, 95-120 mm2, 0,6/1kV
95 mm2 – 120 mm2
Tire hoses repair kit “IZOLRUT 9-O” 
L-780mm, Ø-100mm, 150-185mm2 , 0,6/1kV
150 mm2 – 185 mm2

 

Kits for connecting and repairing tensioned tire cables 3,6/6kVCross-section of connected working conductors
Tire hoses repair kit “IZOLRUT 6-O” 
L-680mm, Ø-72mm, 35-70mm2 , 3,6/6kV
35 mm2 – 70 mm2
Tire hoses repair kit “IZOLRUT 8-O” 
L-700mm, Ø-98mm, 95-120 mm2, 3,6/6kV
95 mm2 – 120 mm2
“IZOLRUT 9-O” 
L-780mm, Ø-100mm, 150-185mm2 , 3,6/6kV
150 mm2 – 185 mm2

 

Kits for connecting and repairing cables to voltage 0,6/1kVCross-section of connected working conductors
Cable repair kit “IZOLRUT 6-K” 
L-680mm, Ø-72mm, 35-70mm2 , 0,6/1kV
35 mm2 – 70 mm2
Cable repair kit “IZOLRUT 8-K” 
L-700mm, Ø-98mm, 95-120 mm2, 0,6/1kV
95 mm2 – 120 mm2
Cable repair kit “IZOLRUT 9-K” 
L-780mm, Ø-100mm, 150-185mm2 , 0,6/1kV
150 mm2 – 185 mm2

 

Kits for connecting and repairing cables to voltage 3,6/6kVCross-section of connected working conductors
Cable repair kit “IZOLRUT 6-K” 
L-680mm, Ø-72mm, 35-70mm2 , 3,6/6kV
35 mm2 – 70 mm2
Cable repair kit “IZOLRUT 8-K” 
L-700mm, Ø-98mm, 95-120 mm2, 3,6/6kV
95 mm2 – 120 mm2
Cable repair kit “IZOLRUT 9-K” 
L-780mm, Ø-100mm, 150-185mm2 , 3,6/6kV
150 mm2 – 185 mm2
Kits for connecting and repairing shielded cables or wires without voltage armor 6/10kVCross-section of connected working conductors
Cable repair kit “IZOLRUT 6” 
L-680mm, Ø-72mm, 35-70mm2 , 6/10kV
35 mm2 – 70 mm2
Cable repair kit “IZOLRUT 8” 
L-700mm, Ø-98mm, 95-120 mm2, 6/10kV
95 mm2 – 120 mm2
Cable repair kit “IZOLRUT 9” 
L-780mm, Ø-100mm, 150-185mm2 , 6/10kV
150 mm2 – 185 mm2
Kits for connecting and repairing cables or shielded wires with armor for voltage 6/10kVCross-section of connected working conductors
Cable repair kit “IZOLRUT 7-P” 
L-680mm, Ø-72mm, 35-70mm2 , 6/10kV
35 mm2 – 70 mm2
Cable repair kit “IZOLRUT 9-P” 
L-700mm, Ø-98mm, 95-120 mm2, 6/10kV
95 mm2 – 120 mm2
Cable repair kit “IZOLRUT 12-P” 
L-780mm, Ø-100mm, 150-185mm2 , 6/10kV
150 mm2 – 185 mm2

 

Selection of IZOLRUT sets for the types of repaired tire hoses

Cable type Cross-section and number of veinsIZOLRUT set type
YnOGY5×2,5mm2 IZOLRUT 2-O
5×4,0mm2IZOLRUT 2-O
4×6+4,0mm2IZOLRUT 3-O
4×10+6,0mm2IZOLRUT 4-O
YnOGYek 5×2,5mm2IZOLRUT 3-O
5×4,0mm2IZOLRUT 3-O
4×6+4,0mm2IZOLRUT 4-O
4×10+6,0mm2IZOLRUT 4-O
PROTOMONT (V) NSSHCGEOEU, 
PROTOMONT NSSHOEU, 
PROTOMONT (V) NTSKCGECWOEU, 
OnGcekż/w-G, O2nGcekż/w-G, 
OnGcekż/w-GW and O2nGcekż/w-GW, OnGcekż-G,  O2nGcekż-G, 
OnGcekż-GW oraz O2nGcekż/w-GW 
3×16+10+3×2,5mm2 IZOLRUT 5-O
3×25+16+3×2,5mm2IZOLRUT 6-O
3×35+16+3×2,5mm2IZOLRUT 6-O
3×50+25+3×4,0mm2IZOLRUT 6-O *
3×70+25+3×4,0mm2IZOLRUT 6-O *
3×95+35+3×4,0mm2IZOLRUT 8 – O *

* – a repair kit should be used when reconstructing a longer length of helix cord tire (up to approx. 900mm) IZOLRUT 9-O

 

  • flexibility of the repair site connecting cables or wires,
  • the water resistance of the set is additionally improved by the use of a caulking putty,
  • there is no need to use a burner as in the heat-shrinkable technology,
  • it is not necessary to solder the grounding sleeve,
  • high durability and high technical parameters. 
  • repair kits type IZOLRUT can be used in all conditions, as well as in underground workings of mining plants, in areas with any methane concentration,
  • The kits can be used to connect and repair cables and wires of a wide variety of cross-sections as shown in the tables below,
  • the ability to repair damage to a cable or wire in a very short time, minimizing the downtime of machines and devices to a minimum,
  • cables / wires can be put into operation immediately after repair or joining ,
  • the technology is based on the use of the best Temflex insulating tapes available on the market, semi-conductive and copper braids manufactured by 3M,
  • in repair kits type IZOLRUT the need to use glue and sealing compound has been eliminated,
  • much greater durability and much higher mechanical and electrical parameters than sets from other companies,
  • the cost of performing a repair with a kit IZOLRUT is much lower than third-party flood joint kits. 
  1. flame retardant, cold shrinkable tubing, IZOLRUT type, with dimensions matched to the diameter of the cable,
  2. insulating tape Temflex prod. 3M (auxiliary tape),
  3. insulating tape no.23 prod. from 3M,
  4. tape made of semi-conductive compound type “P” or tape No. 13 prod. from 3M,
  5. tape braided copper wires or tape No. 24 prod. from 3M,
  6. gasoline solvent,
  7. 6mm rubber cord2,
  8. cotton cloth,
  9. bare copper wire, 1mm cross-section2,
  10. silicone caulking putty,
  11. 4mm copper line2,
  12. self-adhesive label. 

Additionally, for connection works, use sleeve couplings of an approved type (cable connectors for cables or wire connectors for cables) for a voltage of 0.6 / 1 kV. The number and cross-section of the connectors should be matched to the number and cross-section of the working conductors, the protective conductor and possibly auxiliary conductors. 

  1. when connecting mining power cables with insulation, sheath and thermoplastic shields for voltage 0.6 / 1 kV and 3.6 / 6 kV and cross-sections of working conductors 35 – 185mm2,
  2. when connecting and repairing mining sheath cables with cross-sections of working conductors 25 – 95mm2,
  3. for ad hoc and current repairs of tires of tire cables for voltage 0.6 / 1 kV, 1.9 / 3.3 kV, 3.6 / 6 kV used to supply mobile receivers in underground mining plants,
    • PROTOMONT(V) NSSHCGEOEU at rated voltage. 0,6/1 kV with single and two systems of working conductors,
    • PROTOMONT NSSHOEU na rated voltage 0,6/1 kV.
    • PROTOMONT (V) NTSKCGECWOEU at rated voltage 3,6/6 kV,
    • OnGcekż/w-G, O2nGcekż/w-G, OnGcekż/w-GW and O2nGcekż/w-GW at rated voltage 3,6/6 kV,
    • OnGcekż-G, O2nGcekż-G, OnGcekż-GW and O2nGcekż/w-GW at rated voltage0,6/1 kV with single and two systems of working conductors
  4. when connecting screened signaling cables to a rated voltage not exceeding 0.6 / 1 kV,
    • YnHKGSY, YnHKGSX, YnHKGSLY, YnHKGSLYkon, YHKGSYF(t,tl,o,p)yn, YHKGSXF(t,tl,o,p)yn
    • YnStYekżi-G
  5. when connecting unshielded signaling cables to rated voltage not exceeding 0.6 / 1 kV,
    • YnKGSLY, YnKGSLX, YnKGSLYkon, YnKGSLXkon, YKGSYF(t,tl,o,p)yn, YKGSXF(t,tl,o,p)yn for rated voltages from 150/250 V to 0.6 / 1 kV
    • OnD for rated voltage 450/750 V
    • YnStY-G for rated voltage 300/500 V
  6. when connecting mining telecommunications cables,
    • YnTKGX oraz YTKGXF(t,tl,o,p)yn
  7. when connecting telecommunications cables for opencast Mining Plants,
    • OnTGekf-G i OnTGekn-G (ekf)(ekn)
  8. when connecting shielded signaling and telecommunications cables,
    • YnHSTKG(Y,X) oraz YHSTKG(Y,X)F(t,tl,o,p)yn
  9. when connecting shielded signaling and telecommunications cables,
    • YnSTKG(Y,X) oraz YSTKG(Y,X)F(t,tl,o,p)yn

 

Admission:

Repair kits IZOLRUT based on “A detailed description of the universal technology…” on the basis of Technical Opinion No. 2444/2011 & nbsp; Instytut Technik Innowacyjnych EMAG , Expert for mining plant operations, Authorization of the President of the State Mining Authority no. 205/2011 of 18 January 2011. L.dz.GEM / 480/0020/10/11/00958 / KR / GL can be used in underground workings of mining plants. & Nbsp;

A detailed description of the universal technology of joining and repairing mining cables and tire wires to a rated voltage not exceeding 3.6 / 6kV using cold-shrinkable materials of the “IZOLRUT” type has a new Expert’s Opinion No. 01/11/2016 of 03/11/2016 issued by the Research Center and Certification Institutes of Innovative Technologies EMAG in Katowice.

 

Download the manual: